DLEX0001, DLEX0001TM, DLEX2450, DLEX2450V, DLEX2450W, DLEX2550, DLEX2550V, DLEX2550W, DLEX2650, DLEX2650V, DLEX2650W, DLEX2655, DLEX2655V, DLEX2701, DLEX2701V, DLEX2801, DLEX2801W, DLEX2901, DLEX2901V, DLEX3001, DLEX3001P, DLEX3001R, DLEX3001W, DLEX3070, DLEX3070V, DLEX3070W, DLEX3250, DLEX3250V, DLEX3250W, DLEX3360, DLEX3360V, DLEX3360W, DLEX3370, DLEX3370V, DLEX3370W, DLEX3470, DLEX3470V, DLEX3470W, DLEX3550, DLEX3550V, DLEX3550W, DLEX3570, DLEX3570V, DLEX3570W, DLEX3650, DLEX3650V, DLEX3875, DLEX3875V, DLEX3885, DLEX3885W, DLEX4070, DLEX4070V, DLEX4070W, DLEX4270, DLEX4270V, DLEX4270W, DLEX5101, DLEX5101V, DLEX5101W, DLEX5170, DLEX5170V, DLEX5170W, DLEX5175, DLEX5175V, DLEX5680, DLEX5680V, DLEX5680W, DLEX5780, DLEX5955, DLEX8000, DLEX8100, DLEX8500, DLEX8900, DLEX8980, DLGX0002, DLGX0002TM, DLGX2451, DLGX2451V, DLGX2451W, DLGX2502, DLGX2502W, DLGX2551, DLGX2551V, DLGX2551W, DLGX2651, DLGX2651V, DLGX2651W, DLGX2656, DLGX2656V, DLGX2802, DLGX2802W, DLGX2902, DLGX2902V, DLGX3002, DLGX3002P DLGX3002R, DLGX3002W, DLGX3071, DLGX3071V, DLGX3071W, DLGX3251, DLGX3251V, DLGX3251W, DLGX3361, DLGX3361V, DLGX3361W, DLGX3371, DLGX3371V, DLGX3371W, DLGX3471, DLGX3471V, DLGX3471W, DLGX3551, DLGX3551V, DLGX3551W, DLGX3651, DLGX3651V, DLGX3751, DLGX3751W, DLGX3876, DLGX3876V, DLGX3886, DLGX3886W, DLGX4071, DLGX4071V, DLGX4071W, DLGX4271, DLGX4271V, DLGX4271W, DLGX5102, DLGX5102V, DLGX5102W, DLGX5171, DLGX5171V, DLGX5171W, DLGX5176, DLGX5176V, DLGX5681, DLGX5681W, DLGX5781, DLGX5966, DLGX8001, DLGX8101, DLGX8501, DLGX8901, DLGX8981
More Time + Less Time + Power
Unit must be in Standby (unit plugged in, display off).
Press “POWER” while pressing “MORE TIME”, and “LESS TIME”.
WARNING
Dryer service tests should only be used for testing. Do not use these tests other than specified.
- Do not activate the heater manually.
- Do not press the door switch to operate the heater with the door open.
Activating the heater manually the door open may trip the thermostat attached to the heater.
| # | CHECKING ACTION | DISPLAY | CHECKING |
| 0 | Electric control & Temperature sensor | L06 (Elec. Type) | STANDARD |
| L07 (Gas Type) | |||
| U- | MAIN PROGRAM | ||
| d- | DISPLAY PROGRAM | ||
| tE | Thermistor open | ||
| Thermistor shorted | |||
| 1 | Motor + Controller | 30–239 | Motor runs |
| Measured Moisture Value | |||
| Displays Moisture Sensor Operation: | |||
| Higher number is drier | If moisture sensor is contacted with damp cloth. The display number is below 180, in normal condition. | ||
| 2 | ELECTRIC TYPE | Temp (5~70) °C | ELECTRIC TYPE: |
| Motor + Heater 1 (2700W) | Heater 1 is energized – 2700 W | ||
| GAS TYPE | GAS TYPE: | ||
| Motor only | Gas valve is not energized | ||
| (Temperature in the drum is displayed in degrees C.) | |||
| 3 | ELECTRIC TYPE | Temp (5~70) °C | ELECTRIC TYPE: |
| Motor + Heater 1 + Heater 2 (5400W) | Heater 1 and heater 2 are energized – 5400 W | ||
| GAS TYPE | GAS TYPE: Gas valve is energized | ||
| Motor + Gas Valve | (Temperature in the drum is displayed in degrees C.) | ||
| 4 | ELECTRIC TYPE | Water Supply Valve | Mist Valve |
| Mist Valve ON | |||
| Motor + Heater 1 + Heater 2 OFF | |||
| GAS TYPE | |||
| Mist Valve ON | |||
| Motor OFF | |||
| Gas valve OFF | |||
| 5 | Loads OFF | 0 | Water Level Sensor |
| 6 | Loads OFF | POWER OFF | |
| Controller OFF |
Special note for moisture tests:
Some models only have a two digit readout and will only display the first two digits of the moisture value.
Example: unit is dry and moisture value will read 23 instead of 239 which is a very dry value. If you put a damp cloth on the moisture bars it will go down to around 7 or 6.
Some models only have a two digit readout and will only display the first two digits of the moisture value.
Example: unit is dry and moisture value will read 23 instead of 239 which is a very dry value. If you put a damp cloth on the moisture bars it will go down to around 7 or 6.