DLEX0001, DLEX0001TM, DLEX2450, DLEX2450V, DLEX2450W, DLEX2550, DLEX2550V, DLEX2550W, DLEX2650, DLEX2650V, DLEX2650W, DLEX2655, DLEX2655V, DLEX2701, DLEX2701V, DLEX2801, DLEX2801W, DLEX2901, DLEX2901V, DLEX3001, DLEX3001P, DLEX3001R, DLEX3001W, DLEX3070, DLEX3070V, DLEX3070W, DLEX3250, DLEX3250V, DLEX3250W, DLEX3360, DLEX3360V, DLEX3360W, DLEX3370, DLEX3370V, DLEX3370W, DLEX3470, DLEX3470V, DLEX3470W, DLEX3550, DLEX3550V, DLEX3550W, DLEX3570, DLEX3570V, DLEX3570W, DLEX3650, DLEX3650V, DLEX3875, DLEX3875V, DLEX3885, DLEX3885W, DLEX4070, DLEX4070V, DLEX4070W, DLEX4270, DLEX4270V, DLEX4270W, DLEX5101, DLEX5101V, DLEX5101W, DLEX5170, DLEX5170V, DLEX5170W, DLEX5175, DLEX5175V, DLEX5680, DLEX5680V, DLEX5680W, DLEX5780, DLEX5955, DLEX8000, DLEX8100, DLEX8500, DLEX8900, DLEX8980, DLGX0002, DLGX0002TM, DLGX2451, DLGX2451V, DLGX2451W, DLGX2502, DLGX2502W, DLGX2551, DLGX2551V, DLGX2551W, DLGX2651, DLGX2651V, DLGX2651W, DLGX2656, DLGX2656V, DLGX2802, DLGX2802W, DLGX2902, DLGX2902V, DLGX3002, DLGX3002P DLGX3002R, DLGX3002W, DLGX3071, DLGX3071V, DLGX3071W, DLGX3251, DLGX3251V, DLGX3251W, DLGX3361, DLGX3361V, DLGX3361W, DLGX3371, DLGX3371V, DLGX3371W, DLGX3471, DLGX3471V, DLGX3471W, DLGX3551, DLGX3551V, DLGX3551W, DLGX3651, DLGX3651V, DLGX3751, DLGX3751W, DLGX3876, DLGX3876V, DLGX3886, DLGX3886W, DLGX4071, DLGX4071V, DLGX4071W, DLGX4271, DLGX4271V, DLGX4271W, DLGX5102, DLGX5102V, DLGX5102W, DLGX5171, DLGX5171V, DLGX5171W, DLGX5176, DLGX5176V, DLGX5681, DLGX5681W, DLGX5781, DLGX5966, DLGX8001, DLGX8101, DLGX8501, DLGX8901, DLGX8981

More Time + Less Time + Power

Unit must be in Standby (unit plugged in, display off).
Press “POWER” while pressing “MORE TIME”, and “LESS TIME”.

WARNING

Dryer service tests should only be used for testing. Do not use these tests other than specified. 

  • Do not activate the heater manually. 
  • Do not press the door switch to operate the heater with the door open.

Activating the heater manually the door open may trip the thermostat attached to the heater.

#CHECKING ACTIONDISPLAYCHECKING
0Electric control & Temperature sensorL06 (Elec. Type)STANDARD
L07 (Gas Type)
 U-MAIN PROGRAM
 d-DISPLAY PROGRAM
 tEThermistor open
  Thermistor shorted
1Motor + Controller30–239Motor runs
Measured Moisture Value 
 Displays Moisture Sensor Operation:
Higher number is drierIf moisture sensor is contacted with damp cloth. The display number is below 180, in normal condition.
2ELECTRIC TYPETemp (5~70) °CELECTRIC TYPE:
Motor + Heater 1 (2700W)Heater 1 is energized – 2700 W
  
GAS TYPEGAS TYPE:
Motor onlyGas valve is not energized
 (Temperature in the drum is displayed in degrees C.)
3ELECTRIC TYPETemp (5~70) °CELECTRIC TYPE:
Motor + Heater 1 + Heater 2 (5400W)Heater 1 and heater 2 are energized – 5400 W
  
GAS TYPEGAS TYPE: Gas valve is energized
Motor + Gas Valve(Temperature in the drum is displayed in degrees C.)
4ELECTRIC TYPEWater Supply ValveMist Valve
Mist Valve ON
Motor + Heater 1 + Heater 2 OFF
 
GAS TYPE
Mist Valve ON
Motor OFF
Gas valve OFF
5Loads OFF0Water Level Sensor
6Loads OFF POWER OFF
Controller OFF
Special note for moisture tests:
Some models only have a two digit readout and will only display the first two digits of the moisture value.
Example: unit is dry and moisture value will read 23 instead of 239 which is a very dry value. If you put a damp cloth on the moisture bars it will go down to around 7 or 6.